Firmware update for MES14XX, MES24XX, MES3708P, MES3710P, MES3400-XX. Version 10.3.6.11


MES
21 April 2025
Firmware
Version 10.3.6.11
The firmware and detailed description of the product capabilities are available in the Downloads or on the product page.
Added
- Added a command to delete the ssh server-address setting;
- Added a command that disables comparing the IP address in the Next server IP address field and the IP address in the ip dhcp relay server configuration;
- Added the ability to change the standard buffer utilization values of batch processes;
- Added support for Accounting for Dot1x/MAC using the RADIUS protocol;
- The output of the show interfaces status command looks like a similar command on MES23xx/33xx/35xx/5324 devices.
Fixed
- Improved command stability;
- Fixed the hang of the switch when displaying the current configuration;
- Fixed a bug that leads to a complete loss of device control;
- Fixed a problem with the switch hanging when executing the default interface range;
- Fixed a bug with the speed setting in line telnet/ssh;
- Fixed a bug that caused Web interface pages to not load;
- Fixed an error where the cost in STP was incorrectly calculated for interfaces;
- Fixed a problem with the switch hanging when changing the STP mode from RSTP to RPVST;
- Fixed an issue where there was no L3 access to the switch after reboot;
- Fixed an error that freezes the SSH session when saving the configuration to the SFTP server;
- Fixed an error where the source ip was incorrectly specified in the SNMP response packets;
- Fixed an issue where the POWER-ETHERNET-MIB poll::pethMainPseConsumptionPower returned a value in deciwatts instead of watts;
- Fixed an error that displayed an extra log about duplicating a link local IPv6 address;
- Fixed a dot1x PC authorization error when using RADIUS VLAN Attributes and Voice VLAN together;
- Fixed an error leading to TCP session reset;
- Fixed an error that caused high CPU usage when connected to the switch by a telnet client on TCP port 22.